What are tin whiskers?
Tin whiskers are microscopic conductive filaments that grow spontaneously from pure tin surfaces. They can reach several millimetres in length and bridge adjacent conductors, causing short circuits, arcing or intermittent faults.
Why do tin whiskers form?
Contributing factors include compressive stress in the plating, intermetallic compound formation, thin or uneven plating, mechanical stress and vibration, and thermal cycling. The exact mechanism is still not fully understood despite extensive research.
Does conformal coating prevent tin whiskers?
No. Conformal coating can slow growth and contain shorter whiskers, but it does not remove the underlying cause. Longer whiskers can penetrate the coating over time, so it delays rather than eliminates the risk.
How does alloy conversion mitigate tin whiskers?
Replacing a pure tin finish with a tin-lead alloy removes the conditions under which whiskers form. Under GEIA-STD-0005-2, complete conversion to SnPb allows components to be used at any control level without further mitigation.
Which industries are most affected?
Defence, aerospace, rail, medical and industrial sectors, where equipment stays in service for decades and a whisker-induced failure may appear long after production.
Do you verify the converted finish?
Yes. XRF analysis confirms the elemental composition after conversion, and results are recorded and supplied as part of your documentation.
Can you test components for tin whiskers?
We verify mitigation rather than run whisker growth tests. After alloy conversion, XRF analysis confirms the elemental composition of the new finish and solderability testing can confirm it wets correctly, both documented for your quality file. Accelerated whisker growth testing to JESD201 and JESD22-A121 is a separate environmental test discipline that we do not perform.
What is JESD201 tin whisker testing?
JESD201 is the JEDEC standard that sets acceptance criteria for the whisker susceptibility of tin and tin alloy finishes, used alongside JESD22-A121 which defines how whiskers are measured. Testing exposes samples to temperature cycling and thousands of hours at elevated temperature and humidity, then measures whisker length under magnification. It takes months and requires an environmental test laboratory, so it is normally used to qualify a finish rather than to check a specific delivery.